{"id":8463,"date":"2026-10-16T03:12:32","date_gmt":"2026-10-16T03:12:32","guid":{"rendered":"https:\/\/www.compressorpartsmall.com\/?post_type=product&#038;p=8463"},"modified":"2026-10-16T06:10:15","modified_gmt":"2026-10-16T06:10:15","slug":"atlas-copco-ga-200-pack-ff","status":"publish","type":"product","link":"https:\/\/www.compressorpartsmall.com\/ar\/product\/atlas-copco-ga-200-pack-ff\/","title":{"rendered":"\u0636\u0627\u063a\u0637 \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0644\u0648\u0644\u0628\u064a \u0627\u0644\u062f\u0648\u0627\u0631 \u0627\u0644\u0645\u0632\u0648\u062f \u0628\u062d\u0642\u0646 \u0627\u0644\u0632\u064a\u062a \u0645\u0646 \u0637\u0631\u0627\u0632 Atlas Copco GA 200 (\u062d\u0632\u0645\u0629 FF)"},"content":{"rendered":"<p>The Atlas Copco GA 200 is the fixed-speed workhorse of the GA 180-315 oil-injected platform, the duty class above the GA 90-160 range. It pairs a SmartInjection compression element with an oil-cooled motor rated at 220 kW, and the Full Feature branch adds an integrated refrigerant dryer to the same package. The versions cover the 5.5, 7.5, 8.5 and 10 bar bands in 50 Hz and the 75 to 150 psi bands in 60 Hz, with free air delivery between 458 and 836 l\/s depending on the setting.<\/p>\n<h2>Where the GA 200 Sits in the Oil-Injected Range<\/h2>\n<p>The GA 180-315 platform takes over where the GA 90-160 range ends, and the GA 200 stands at its base with fixed-speed control for steady base-load duty. Plants that have outgrown the GA 160 step up to this rating without changing the service concept or the monitoring tools, and installations with fluctuating demand pair this machine with a VSD unit of the same platform.<\/p>\n<p>\u0647\u0646\u0627\u0643 \u0627\u0644\u0622\u0644\u0627\u0641 \u0645\u0646 \u0636\u0648\u0627\u063a\u0637 \u0627\u0644\u0647\u0648\u0627\u0621 \u0645\u0646 \u0637\u0631\u0627\u0632 GA \u062a\u0639\u0645\u0644 \u0641\u064a \u062c\u0645\u064a\u0639 \u0623\u0646\u062d\u0627\u0621 \u0627\u0644\u0639\u0627\u0644\u0645 \u0636\u0645\u0646 \u0647\u0630\u0647 \u0627\u0644\u0641\u0626\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u064a\u0629\u060c \u0648\u062a\u062a\u0631\u0643\u0632 \u0647\u0630\u0647 \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0641\u064a \u0627\u0644\u0623\u0645\u0627\u0643\u0646 \u0627\u0644\u062a\u064a \u064a\u064f\u0633\u062a\u062e\u062f\u0645 \u0641\u064a\u0647\u0627 \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0645\u0636\u063a\u0648\u0637 \u0639\u0644\u0649 \u0645\u062f\u0627\u0631 \u0627\u0644\u0633\u0627\u0639\u0629: \u0645\u062b\u0644 \u0645\u0646\u0627\u062c\u0645 \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0645\u062d\u0637\u0627\u062a \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0645\u0639\u0627\u062f\u0646 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0623\u0633\u0645\u0646\u062a \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0648\u0631\u0642. \u0648\u062a\u062a\u0646\u0648\u0639 \u0627\u0644\u0645\u0647\u0627\u0645 \u0628\u064a\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0623\u062f\u0648\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0626\u064a\u0629 \u0648\u0627\u0644\u0645\u0634\u063a\u0644\u0627\u062a \u0648\u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a\u060c \u0648\u0635\u0648\u0644\u0627\u064b \u0625\u0644\u0649 \u0622\u0644\u0627\u062a \u0627\u0644\u062a\u0647\u0648\u064a\u0629 \u0648\u0627\u0644\u062a\u0639\u0628\u0626\u0629 \u0648\u0627\u0644\u062a\u062d\u0645\u064a\u0644 \u0639\u0644\u0649 \u0627\u0644\u0645\u0646\u0635\u0627\u062a\u060c \u0648\u0625\u0632\u0627\u0644\u0629 \u0627\u0644\u0633\u062e\u0627\u0645\u060c \u0648\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0631\u0645\u0627\u062f \u0627\u0644\u0645\u062a\u0637\u0627\u064a\u0631\u060c \u0648\u0627\u0644\u0646\u0642\u0644 \u0627\u0644\u0647\u0648\u0627\u0626\u064a \u0644\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u062e\u0627\u0645.<\/p>\n<h3>\u0625\u0635\u062f\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0632\u0645\u0629 \u0648\u0627\u0644\u0625\u0635\u062f\u0627\u0631\u0627\u062a \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0627\u0644\u0645\u064a\u0632\u0627\u062a<\/h3>\n<p>Two names describe the branches of the GA 200, and each adds one fact:<\/p>\n<ul>\n<li>\u0648\u062d\u062f\u0629 \u0627\u0644\u062a\u0639\u0628\u0626\u0629 \u2014 \u062a\u0648\u0641\u0631 \u0648\u062d\u062f\u0629 \u0627\u0644\u0636\u0627\u063a\u0637 \u0647\u0648\u0627\u0621\u064b \u0645\u0636\u063a\u0648\u0637\u064b\u0627 \u063a\u064a\u0631 \u0645\u0639\u0627\u0644\u062c \u0644\u0644\u0634\u0628\u0643\u0627\u062a \u0627\u0644\u062a\u064a \u062a\u062d\u062a\u0648\u064a \u0639\u0644\u0649 \u0646\u0638\u0627\u0645 \u062e\u0627\u0631\u062c\u064a \u0644\u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0647\u0648\u0627\u0621 \u0641\u064a \u0627\u0644\u0645\u0631\u062d\u0644\u0629 \u0627\u0644\u0644\u0627\u062d\u0642\u0629.<\/li>\n<li>FF \u2014 \u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0643\u0627\u0645\u0644\u0629: \u062a\u0634\u062a\u0645\u0644 \u0627\u0644\u062d\u0632\u0645\u0629 \u0639\u0644\u0649 \u0645\u062c\u0641\u0641 \u064a\u0639\u0645\u0644 \u0628\u0627\u0644\u0645\u0628\u0631\u062f\u060c \u0628\u062d\u064a\u062b \u062a\u062a\u0645 \u0639\u0645\u0644\u064a\u0629 \u0627\u0644\u062a\u062c\u0641\u064a\u0641 \u062f\u0627\u062e\u0644 \u0627\u0644\u0636\u0627\u063a\u0637 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u062c\u0627\u0646\u0628\u0647\u060c \u062f\u0648\u0646 \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0623\u064a \u0623\u0639\u0645\u0627\u0644 \u062a\u0631\u0643\u064a\u0628 \u0625\u0636\u0627\u0641\u064a\u0629 \u0644\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0646\u0627\u0628\u064a\u0628.<\/li>\n<\/ul>\n<p>The GA 200 is built as the GA 200 &#8211; 5.5 bar, &#8211; 7.5 bar, &#8211; 8.5 bar and &#8211; 10 bar versions at 50 Hz, and as the GA 200 &#8211; 75 psi, &#8211; 100 psi, &#8211; 125 psi and &#8211; 150 psi versions at 60 Hz. Every version combines with both the Pack and the Full Feature scope, so a plant picks the pressure band first and the depth of air treatment second.<\/p>\n<figure id=\"attachment_8456\" class=\"wp-caption aligncenter\" style=\"width: 300px;\" aria-describedby=\"caption-attachment-8456\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-8456\" src=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-300x300.webp\" alt=\"\u0623\u0637\u0644\u0633 \u0643\u0648\u0628\u0643\u0648 GA 200 FF (1)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-300x300.webp 300w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-150x150.webp 150w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-768x768.webp 768w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-600x600.webp 600w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1-100x100.webp 100w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-1.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-8456\" class=\"wp-caption-text\">\u0623\u0637\u0644\u0633 \u0643\u0648\u0628\u0643\u0648 GA 200 FF (1)<\/figcaption><\/figure>\n<h2>Technical Specifications of the GA 200<\/h2>\n<p>The table below condenses the GA 200 into its headline figures:<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>\u0627\u0644\u0642\u064a\u0645\u0629<\/th>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0637\u0631\u0627\u0632<\/td>\n<td>Atlas Copco GA 200<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0648\u0639 \u0627\u0644\u0636\u0627\u063a\u0637<\/td>\n<td>\u0645\u0636\u062e\u0629 \u0644\u0648\u0644\u0628\u064a\u0629 \u062f\u0648\u0627\u0631\u0629 \u0645\u0632\u0648\u062f\u0629 \u0628\u062d\u0642\u0646 \u0627\u0644\u0632\u064a\u062a\u060c \u0645\u0628\u0631\u062f\u0629 \u0628\u0627\u0644\u0647\u0648\u0627\u0621 \u0623\u0648 \u0628\u0627\u0644\u0645\u0627\u0621<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a \u0627\u0644\u0633\u0639\u0629<\/td>\n<td>\u0633\u0631\u0639\u0629 \u062b\u0627\u0628\u062a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0642\u062f\u0631\u0629 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u0631\u0643\u0628<\/td>\n<td>220 kW \/ 295 hp<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0625\u0635\u062f\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0636\u063a\u0637<\/td>\n<td>5.5 \/ 7.5 \/ 8.5 \/ 10 \u0628\u0627\u0631 (50 \u0647\u0631\u062a\u0632)\u061b 75 \/ 100 \/ 125 \/ 150 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629 (60 \u0647\u0631\u062a\u0632)<\/td>\n<\/tr>\n<tr>\n<td>\u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>5.5-10.9 \u0628\u0627\u0631 (e) \/ 80-158 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629 \u062d\u0633\u0628 \u0627\u0644\u0625\u0635\u062f\u0627\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0648\u0635\u064a\u0644 \u0645\u062c\u0627\u0646\u064a \u0639\u0628\u0631 \u0627\u0644\u062c\u0648<\/td>\n<td>440-836 l\/s by version (26.4-50.2 m\u00b3\/min \/ 932-1,771 cfm)<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0635\u0648\u062a<\/td>\n<td>70-77 dB(A) at the work station by version<\/td>\n<\/tr>\n<tr>\n<td>\u0646\u0642\u0637\u0629 \u0627\u0644\u0646\u062f\u0649\u060c \u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0643\u0627\u0645\u0644\u0629<\/td>\n<td>3 \u062f\u0631\u062c\u0627\u062a \u0645\u0626\u0648\u064a\u0629 \/ 37 \u062f\u0631\u062c\u0629 \u0641\u0647\u0631\u0646\u0647\u0627\u064a\u062a \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u0631\u062c\u0639\u064a\u0629 \u0644\u0644\u0645\u062c\u0641\u0641<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u062f\u062f<\/td>\n<td>50 \u0647\u0631\u062a\u0632 \u064860 \u0647\u0631\u062a\u0632<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u0642\u0646\u0646\u0629 \u0639\u0646\u062f 50 \u0647\u0631\u062a\u0632<\/h3>\n<p>\u062a\u0648\u0641\u0631 \u0643\u0644 \u0646\u0633\u062e\u0629 \u062a\u0639\u0645\u0644 \u0628\u062a\u0631\u062f\u062f 50 \u0647\u0631\u062a\u0632 \u062a\u062f\u0641\u0642\u064b\u0627 \u0648\u0627\u062d\u062f\u064b\u0627 \u0645\u0635\u0646\u0651\u0641\u064b\u0627 \u0639\u0646\u062f \u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0643\u0627\u0645\u0644. \u0648\u064a\u062a\u0645 \u0642\u064a\u0627\u0633 \u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u062f\u0641\u0642 \u0627\u0644\u064a\u0648\u0645\u064a (FAD) \u0644\u0644\u0646\u0633\u062e\u0629 \u0627\u0644\u0642\u064a\u0627\u0633\u064a\u0629 \u0639\u0646\u062f \u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0643\u0627\u0645\u0644\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0634\u062a\u0645\u0644 \u0627\u0644\u0646\u0633\u062e\u0629 \u0627\u0644\u0643\u0627\u0645\u0644\u0629 \u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0639\u0644\u0649 \u0645\u062c\u0641\u0641 \u0645\u062f\u0645\u062c \u064a\u062a\u0645\u064a\u0632 \u0628\u0627\u0646\u062e\u0641\u0627\u0636 \u0636\u0626\u064a\u0644 \u0641\u064a \u0627\u0644\u0636\u063a\u0637:<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0625\u0635\u062f\u0627\u0631<\/th>\n<th>\u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<th>FAD (\u0644\u062a\u0631\/\u062b\u0627\u0646\u064a\u0629)<\/th>\n<th>\u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u062f\u0641\u0642 (\u0645\u00b3\/\u062f\u0642\u064a\u0642\u0629)<\/th>\n<th>FAD (\u0642\u062f\u0645 \u0645\u0643\u0639\u0628 \u0641\u064a \u0627\u0644\u062f\u0642\u064a\u0642\u0629)<\/th>\n<th>\u0627\u0644\u0636\u0648\u0636\u0627\u0621<\/th>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 5.5 bar<\/td>\n<td>5.5 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 80 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>833.2<\/td>\n<td>50.0<\/td>\n<td>1,765<\/td>\n<td>71 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 7.5 bar<\/td>\n<td>7.5 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 109 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>729<\/td>\n<td>43.7<\/td>\n<td>1,545<\/td>\n<td>74 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 8.5 bar<\/td>\n<td>8.5 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 123 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>686<\/td>\n<td>41.2<\/td>\n<td>1,454<\/td>\n<td>70 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 10 bar<\/td>\n<td>10 \u0628\u0627\u0631(\u0639\u0627\u0631\u064a) \/ 145 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>624<\/td>\n<td>37.4<\/td>\n<td>1,322<\/td>\n<td>70 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The installed motor power stays at 220 kW across all versions. The 5.5 bar version tops the range at 833.2 l\/s (1,765 cfm), and moving to the 10 bar band trades flow for pressure at 624 l\/s (1,322 cfm). In the Full Feature build the working pressure reads 5.3 bar(e) \/ 77 psig on the 5.5 bar version and 9.8 bar(e) \/ 142 psig on the 10 bar version, which reflects the pressure drop of the integrated dryer.<\/p>\n<h3>\u0627\u0644\u0628\u064a\u0627\u0646\u0627\u062a \u0627\u0644\u0645\u0642\u0646\u0646\u0629 \u0639\u0646\u062f 60 \u0647\u0631\u062a\u0632<\/h3>\n<p>The 60 Hz versions cover four bands from 75 to 150 psi, with the motor rated at 295 hp:<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0625\u0635\u062f\u0627\u0631<\/th>\n<th>\u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<th>FAD (\u0644\u062a\u0631\/\u062b\u0627\u0646\u064a\u0629)<\/th>\n<th>\u0645\u0639\u062f\u0644 \u0627\u0644\u062a\u062f\u0641\u0642 (\u0645\u00b3\/\u062f\u0642\u064a\u0642\u0629)<\/th>\n<th>FAD (\u0642\u062f\u0645 \u0645\u0643\u0639\u0628 \u0641\u064a \u0627\u0644\u062f\u0642\u064a\u0642\u0629)<\/th>\n<th>\u0627\u0644\u0636\u0648\u0636\u0627\u0621<\/th>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 75 psi<\/td>\n<td>5.5 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 80 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>836<\/td>\n<td>50.2<\/td>\n<td>1,771<\/td>\n<td>77 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 100 psi<\/td>\n<td>7.4 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 107 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>735<\/td>\n<td>44.1<\/td>\n<td>1,557<\/td>\n<td>76 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 125 psi<\/td>\n<td>9.1 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 132 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>660<\/td>\n<td>39.6<\/td>\n<td>1,398<\/td>\n<td>76 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<tr>\n<td>GA 200 &#8211; 150 psi<\/td>\n<td>10.9 \u0628\u0627\u0631 (\u0639\u0627\u0631\u064a) \/ 158 \u0631\u0637\u0644 \u0644\u0643\u0644 \u0628\u0648\u0635\u0629 \u0645\u0631\u0628\u0639\u0629<\/td>\n<td>591<\/td>\n<td>35.5<\/td>\n<td>1,252<\/td>\n<td>75 \u062f\u064a\u0633\u064a\u0628\u0644 (A)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The 75 psi version peaks at 836 l\/s (1,771 cfm), and the 150 psi version delivers 591 l\/s (1,252 cfm). FAD is measured according to ISO 1217, Annex C, edition 4 (2009), at an absolute inlet pressure of 1 bar and an intake temperature of 20 degrees Celsius.<\/p>\n<h3>\u0627\u0644\u0623\u0628\u0639\u0627\u062f \u0648\u0627\u0644\u0648\u0632\u0646<\/h3>\n<p>The footprint of the GA 200 depends on the branch, and the integrated dryer of the Full Feature adds length to the package:<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<th>\u0641\u0631\u0639<\/th>\n<th>\u0627\u0644\u0648\u0632\u0646<\/th>\n<th>\u0627\u0644\u0623\u0628\u0639\u0627\u062f (\u0627\u0644\u0637\u0648\u0644 \u00d7 \u0627\u0644\u0639\u0631\u0636 \u00d7 \u0627\u0644\u0627\u0631\u062a\u0641\u0627\u0639)<\/th>\n<\/tr>\n<tr>\n<td>GA 200, Pack, air-cooled<\/td>\n<td>5,900 kg \/ 13,007 lb<\/td>\n<td>4,390 \u00d7 2,090 \u00d7 2,020 \u0645\u0644\u0645 (173 \u00d7 82 \u00d7 79 \u0628\u0648\u0635\u0629)<\/td>\n<\/tr>\n<tr>\n<td>GA 200, Full Feature, air-cooled<\/td>\n<td>6,500 kg \/ 14,330 lb<\/td>\n<td>5,020 \u00d7 2,090 \u00d7 2,020 \u0645\u0644\u0645 (198 \u00d7 82 \u00d7 79 \u0628\u0648\u0635\u0629)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The water-cooled packages share the width and height with 3,130 mm length for the Pack and 3,760 mm for the Full Feature, because the dryer module replaces part of the cooler section. The Full Feature package is 630 mm longer and 600 kg heavier than the air-cooled Pack, so floor planning comes down to the length difference between the two branches.<\/p>\n<h2>\u0646\u0638\u0627\u0645 \u00abSmartInjection\u00bb \u0648\u0646\u0638\u0627\u0645 \u0646\u0642\u0644 \u0627\u0644\u062d\u0631\u0643\u0629 \u0627\u0644\u0645\u0628\u0631\u062f \u0628\u0627\u0644\u0632\u064a\u062a<\/h2>\n<p>\u062a\u064f\u0639\u062f \u062a\u0642\u0646\u064a\u0629 \u00abSmartInjection\u00bb \u062c\u0648\u0647\u0631 \u0647\u0630\u0627 \u0627\u0644\u0639\u0646\u0635\u0631. \u0641\u0647\u064a \u062a\u0648\u0641\u0631 \u0627\u0644\u0643\u0645\u064a\u0629 \u0627\u0644\u062f\u0642\u064a\u0642\u0629 \u0645\u0646 \u0627\u0644\u0632\u064a\u062a \u0627\u0644\u062a\u064a \u064a\u062d\u062a\u0627\u062c\u0647\u0627 \u0639\u0646\u0635\u0631 \u0627\u0644\u0636\u063a\u0637\u060c \u0645\u0645\u0627 \u064a\u0636\u0645\u0646 \u0639\u0645\u0644 \u0627\u0644\u0639\u0646\u0635\u0631 \u0628\u0623\u0642\u0635\u0649 \u0643\u0641\u0627\u0621\u0629 \u0641\u064a \u0638\u0644 \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u062a\u063a\u064a\u0631\u0629\u060c \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0627\u0644\u0639\u0645\u0644 \u0628\u0645\u0633\u062a\u0648\u0649 \u062b\u0627\u0628\u062a \u064a\u0645\u062b\u0644 \u062d\u0644\u064b\u0627 \u0648\u0633\u0637\u064b\u0627. \u064a\u062a\u062f\u0641\u0642 \u0627\u0644\u0632\u064a\u062a \u0628\u0634\u0643\u0644 \u0645\u0646\u0641\u0635\u0644 \u0625\u0644\u0649 \u0627\u0644\u0645\u062d\u0627\u0645\u0644 \u0644\u0636\u0645\u0627\u0646 \u0639\u0645\u0631 \u0623\u0637\u0648\u0644 \u0648\u0648\u0642\u062a \u062a\u0634\u063a\u064a\u0644 \u0623\u0637\u0648\u0644\u060c \u0643\u0645\u0627 \u0623\u0646 \u0627\u0644\u0645\u062d\u0631\u0643 \u0646\u0641\u0633\u0647 \u0645\u0628\u0631\u062f \u0628\u0627\u0644\u0632\u064a\u062a\u060c \u0645\u0645\u0627 \u064a\u0644\u063a\u064a \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0627\u0644\u062a\u062f\u062e\u0644\u0627\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u062a\u064a \u064a\u062a\u0637\u0644\u0628\u0647\u0627 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u062a\u0642\u0644\u064a\u062f\u064a \u0627\u0644\u0645\u0628\u0631\u062f \u0628\u0627\u0644\u0647\u0648\u0627\u0621. \u0648\u064a\u062d\u062a\u0648\u064a \u0646\u0638\u0627\u0645 \u0627\u0644\u062f\u0641\u0639 \u0639\u0644\u0649 \u0645\u062d\u0631\u0643 \u0645\u0646 \u0641\u0626\u0629 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 IE4\u060c \u0648\u0647\u064a \u0641\u0626\u0629 \u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062a\u064a \u062a\u0637\u0628\u0642\u0647\u0627 \u0634\u0631\u0643\u0629 Atlas Copco \u0639\u0644\u0649 \u0627\u0644\u0622\u0644\u0627\u062a \u0630\u0627\u062a \u0627\u0644\u0633\u0631\u0639\u0629 \u0627\u0644\u062b\u0627\u0628\u062a\u0629 \u0641\u064a \u0647\u0630\u0647 \u0627\u0644\u0645\u0646\u0635\u0629.<\/p>\n<h3>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 IP66 \u0648\u0627\u0644\u0642\u062f\u0631\u0629 \u0639\u0644\u0649 \u0627\u0644\u0639\u0645\u0644 \u0641\u064a \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0628\u064a\u0626\u064a\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629<\/h3>\n<p>The drive train of the GA 200 is IP66 rated, which seals it completely against environmental dust and moisture. That rating is what lets the compressor run reliably in the toughest conditions: cement dust, mine particulates and humid intake air stay outside the drive train. The fixed-speed pack operates at ambient temperatures up to 55 degrees Celsius, and the high ambient variant is available for hotter climates.<\/p>\n<figure id=\"attachment_8457\" class=\"wp-caption aligncenter\" style=\"width: 300px;\" aria-describedby=\"caption-attachment-8457\"><img decoding=\"async\" class=\"size-medium wp-image-8457\" src=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-300x300.webp\" alt=\"Atlas Copco GA 200 FF (2)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-300x300.webp 300w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-150x150.webp 150w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-768x768.webp 768w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-600x600.webp 600w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2-100x100.webp 100w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-2.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-8457\" class=\"wp-caption-text\">Atlas Copco GA 200 FF (2)<\/figcaption><\/figure>\n<h2>\u0627\u0644\u0643\u0641\u0627\u0621\u0629 \u0648\u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629<\/h2>\n<p>Over 80 percent of a compressor lifecycle cost is the energy it consumes, and compressed air generation can account for more than 40 percent of a plant&#8217;s electricity bill. The GA 200 attacks that share at the element and the motor: SmartInjection holds the element at peak efficiency, generous cooling capacity and low internal pressure drops keep the losses down, and the Elektronikon Touch control trims the energy use of the whole package.<\/p>\n<h3>\u0627\u0644\u062a\u062d\u0643\u0645 \u0628\u0646\u0642\u0637\u062a\u064a \u0636\u0628\u0637<\/h3>\n<p>\u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0648\u062d\u062f\u0629 \u0627\u0644\u062a\u062d\u0643\u0645 \u00ab\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0643\u0648\u0646\u00bb\u060c \u062a\u0642\u0648\u0645 \u0627\u0644\u0645\u062d\u0637\u0629 \u0628\u0627\u0644\u062a\u0628\u062f\u064a\u0644 \u0628\u064a\u0646 \u0646\u0642\u0637\u062a\u064a \u0636\u0628\u0637 \u064a\u062f\u0648\u064a\u064b\u0651\u0627 \u0623\u0648 \u0622\u0644\u064a\u064b\u0651\u0627 \u0645\u0646 \u0623\u062c\u0644 \u062a\u062d\u0633\u064a\u0646 \u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u0637\u0627\u0642\u0629 \u0641\u064a \u0623\u0648\u0642\u0627\u062a \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0637\u0644\u0628. \u062a\u0639\u0645\u0644 \u0627\u0644\u062e\u0648\u0627\u0631\u0632\u0645\u064a\u0629 \u0627\u0644\u0645\u062a\u0637\u0648\u0631\u0629 \u0639\u0644\u0649 \u062a\u0634\u063a\u064a\u0644 \u0645\u062d\u0631\u0643 \u0627\u0644\u062f\u0641\u0639 \u0641\u0642\u0637 \u0639\u0646\u062f \u0627\u0644\u062d\u0627\u062c\u0629\u060c \u0648\u0628\u0645\u0627 \u0623\u0646 \u0646\u0642\u0637\u0629 \u0627\u0644\u0636\u0628\u0637 \u0627\u0644\u0645\u0637\u0644\u0648\u0628\u0629 \u064a\u062a\u0645 \u0627\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u064a\u0647\u0627 \u0645\u0639 \u062a\u0642\u0644\u064a\u0644 \u0648\u0642\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0625\u0644\u0649 \u0623\u062f\u0646\u0649 \u062d\u062f\u060c \u0641\u0625\u0646 \u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0644\u0644\u0622\u0644\u0629 \u0630\u0627\u062a \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0623\u0633\u0627\u0633\u064a \u064a\u0638\u0644 \u0639\u0646\u062f \u0627\u0644\u0645\u0633\u062a\u0648\u0649 \u0627\u0644\u0630\u064a \u062a\u0645 \u062a\u0635\u0645\u064a\u0645\u0647\u0627 \u0645\u0646 \u0623\u062c\u0644\u0647.<\/p>\n<h3>\u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0639\u0644\u0649 \u0634\u0643\u0644 \u0645\u0627\u0621 \u0633\u0627\u062e\u0646<\/h3>\n<p>\u064a\u062a\u0623\u0644\u0641 \u0646\u0638\u0627\u0645 \u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a \u0645\u0646 \u0645\u0628\u0627\u062f\u0644 \u062d\u0631\u0627\u0631\u064a \u0645\u062f\u0645\u062c \u0645\u0635\u0646\u0648\u0639 \u0645\u0646 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623 \u0645\u0632\u0648\u062f \u0628\u062f\u0627\u0626\u0631\u0629 \u064a\u062a\u0645 \u0627\u0644\u062a\u062d\u0643\u0645 \u0641\u064a\u0647\u0627 \u0628\u0648\u0627\u0633\u0637\u0629 \u0645\u0646\u0638\u0645 \u062d\u0631\u0627\u0631\u064a. \u0648\u064a\u0633\u062a\u0639\u064a\u062f \u0647\u0630\u0627 \u0627\u0644\u0646\u0638\u0627\u0645 \u0645\u0627 \u064a\u0635\u0644 \u0625\u0644\u0649 78 \u0641\u064a \u0627\u0644\u0645\u0627\u0626\u0629 \u0645\u0646 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u0648\u0644\u062f\u0629 \u0645\u0646 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u062f\u0645\u062c \u0648\u062f\u0627\u0626\u0631\u0629 \u0632\u064a\u062a \u0627\u0644\u0639\u0646\u0635\u0631 \u0641\u064a \u0634\u0643\u0644 \u0645\u0627\u0621 \u062f\u0627\u0641\u0626 \u0623\u0648 \u0645\u0627\u0621 \u0633\u0627\u062e\u0646\u060c \u062f\u0648\u0646 \u0623\u064a \u062a\u0623\u062b\u064a\u0631 \u0633\u0644\u0628\u064a \u0639\u0644\u0649 \u0623\u062f\u0627\u0621 \u0627\u0644\u0636\u0627\u063a\u0637. \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u062a\u064a \u062a\u0639\u062a\u0645\u062f \u0639\u0644\u0649 \u062a\u063a\u0630\u064a\u0629 \u0627\u0644\u063a\u0644\u0627\u064a\u0627\u062a \u0623\u0648 \u0639\u0645\u0644\u064a\u0627\u062a \u0627\u0644\u063a\u0633\u064a\u0644 \u0623\u0648 \u062a\u062f\u0641\u0626\u0629 \u0627\u0644\u0623\u0645\u0627\u0643\u0646\u060c \u0641\u0625\u0646 \u062a\u0644\u0643 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u0633\u062a\u0631\u062f\u0629 \u062a\u062d\u0644 \u0645\u062d\u0644 \u0627\u0644\u0648\u0642\u0648\u062f \u0623\u0648 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0621 \u0627\u0644\u062a\u064a \u0643\u0627\u0646\u062a \u0627\u0644\u0645\u0635\u0646\u0639 \u0633\u062a\u0633\u062a\u0647\u0644\u0643\u0647\u0627 \u0644\u0648\u0644\u0627 \u0630\u0644\u0643.<\/p>\n<figure id=\"attachment_8458\" class=\"wp-caption aligncenter\" style=\"width: 300px;\" aria-describedby=\"caption-attachment-8458\"><img decoding=\"async\" class=\"size-medium wp-image-8458\" src=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-300x300.webp\" alt=\"Atlas Copco GA 200 FF (3)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-300x300.webp 300w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-150x150.webp 150w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-768x768.webp 768w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-600x600.webp 600w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3-100x100.webp 100w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-FF-3.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-8458\" class=\"wp-caption-text\">Atlas Copco GA 200 FF (3)<\/figcaption><\/figure>\n<h2>\u062a\u0642\u0631\u064a\u0631 \u0634\u0627\u0645\u0644: \u0645\u062c\u0641\u0641 \u0627\u0644\u0645\u0628\u0631\u062f \u0627\u0644\u0645\u062f\u0645\u062c<\/h2>\n<p>In the GA 200 Full Feature, the refrigeration dryer is fully integrated in the compressor unit. The all-in-one layout reduces the floor space needed for the compressor room and removes the piping installation work a standalone dryer requires. The pressure dew point of the refrigerant dryer is 3 degrees Celsius at dryer reference conditions, and the dew point is continuously monitored while the machine runs.<\/p>\n<h3>\u0641\u0635\u0644 \u0627\u0644\u0632\u064a\u062a \u0648\u062c\u0648\u062f\u0629 \u0627\u0644\u0647\u0648\u0627\u0621<\/h3>\n<p>\u0623\u0645\u0627 \u0641\u064a\u0645\u0627 \u064a\u062a\u0639\u0644\u0642 \u0628\u0627\u0644\u0632\u064a\u062a\u060c \u0641\u0625\u0646 \u0648\u0639\u0627\u0621 \u0627\u0644\u0641\u0635\u0644 \u0627\u0644\u062c\u062f\u064a\u062f \u064a\u0633\u062a\u062e\u062f\u0645 \u0639\u062f\u0629 \u062e\u0631\u0627\u0637\u064a\u0634 \u0623\u0635\u063a\u0631 \u062d\u062c\u0645\u064b\u0627 \u0628\u062f\u0644\u0627\u064b \u0645\u0646 \u0623\u0633\u0637\u0648\u0627\u0646\u0629 \u0648\u0627\u062d\u062f\u0629 \u0643\u0628\u064a\u0631\u0629\u060c \u0645\u0645\u0627 \u064a\u0628\u0633\u0637 \u0623\u0639\u0645\u0627\u0644 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0648\u064a\u0642\u0635\u0631 \u0645\u062f\u062a\u0647\u0627\u060c \u0648\u064a\u0642\u0644\u0644 \u0625\u0644\u0649 \u0623\u062f\u0646\u0649 \u062d\u062f \u0645\u0646 \u0627\u0646\u062a\u0642\u0627\u0644 \u0627\u0644\u0632\u064a\u062a \u0625\u0644\u0649 \u062a\u064a\u0627\u0631 \u0627\u0644\u0647\u0648\u0627\u0621. \u0643\u0645\u0627 \u062a\u0642\u0644\u0644 \u0627\u0644\u062e\u0631\u0627\u0637\u064a\u0634 \u0627\u0644\u0645\u062a\u0639\u062f\u062f\u0629 \u0627\u0644\u0623\u0635\u063a\u0631 \u062d\u062c\u0645\u064b\u0627 \u0645\u0646 \u0627\u0646\u062e\u0641\u0627\u0636 \u0627\u0644\u0636\u063a\u0637 \u0639\u0628\u0631 \u0627\u0644\u0641\u0627\u0635\u0644\u060c \u0648\u0628\u0627\u0644\u062a\u0627\u0644\u064a \u062a\u062d\u0627\u0641\u0638 \u0627\u0644\u0648\u062d\u062f\u0629 \u0639\u0644\u0649 \u0642\u062f\u0631 \u0623\u0643\u0628\u0631 \u0645\u0646 \u0627\u0644\u062a\u062f\u0641\u0642 \u0639\u0646\u062f \u0627\u0644\u0645\u062e\u0631\u062c.<\/p>\n<h2>\u0627\u0644\u0645\u0631\u0627\u0642\u0628\u0629 \u0648\u0627\u0644\u062a\u062d\u0643\u0645<\/h2>\n<p>The Elektronikon Touch controller runs the GA 200 from one touch display. The controller monitors the running conditions and the maintenance status, and the built-in remote control and notification functions come with a simple integrated webpage as standard. Support covers a wide set of languages, so the same machine serves plants across regions without a local controller variant.<\/p>\n<h3>SMARTLINK \u0648 Optimizer 4.0<\/h3>\n<p>\u064a\u0642\u0648\u0645 \u0646\u0638\u0627\u0645 SMARTLINK \u0628\u0645\u0631\u0627\u0642\u0628\u0629 \u0634\u0628\u0643\u0629 \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0645\u0636\u063a\u0648\u0637 \u0639\u0628\u0631 \u0634\u0628\u0643\u0629 \u0627\u0644\u0625\u064a\u062b\u0631\u0646\u062a: \u062d\u064a\u062b \u062a\u062a\u064a\u062d \u0627\u0644\u062a\u0642\u0627\u0631\u064a\u0631 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u062a\u062a\u0628\u0639 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0641\u064a \u063a\u0631\u0641\u0629 \u0627\u0644\u0636\u0627\u063a\u0637\u060c \u0648\u064a\u062a\u0645 \u0627\u0633\u062a\u0628\u062f\u0627\u0644 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0641\u064a \u0627\u0644\u0648\u0642\u062a \u0627\u0644\u0645\u0646\u0627\u0633\u0628 \u0644\u0644\u062d\u0641\u0627\u0638 \u0639\u0644\u0649 \u0645\u0633\u062a\u0648\u0649 \u0639\u0627\u0644\u064d \u0645\u0646 \u0648\u0642\u062a \u0627\u0644\u062a\u0634\u063a\u064a\u0644\u060c \u0643\u0645\u0627 \u062a\u0633\u0627\u0639\u062f \u0627\u0644\u0625\u0646\u0630\u0627\u0631\u0627\u062a \u0627\u0644\u0645\u0628\u0643\u0631\u0629 \u0639\u0644\u0649 \u062a\u062c\u0646\u0628 \u0627\u0644\u0623\u0639\u0637\u0627\u0644 \u0648\u062e\u0633\u0627\u0626\u0631 \u0627\u0644\u0625\u0646\u062a\u0627\u062c.<\/p>\n<p>\u062a\u064f\u0632\u0648\u064e\u0651\u062f \u0627\u0644\u0645\u0646\u0634\u0622\u062a \u0627\u0644\u062a\u064a \u062a\u0636\u0645 \u0639\u062f\u0629 \u0622\u0644\u0627\u062a \u0628\u0628\u0631\u0646\u0627\u0645\u062c \u00abOptimizer 4.0\u00bb. \u062d\u064a\u062b \u064a\u0639\u0645\u0644 \u0647\u0630\u0627 \u0627\u0644\u0628\u0631\u0646\u0627\u0645\u062c \u0639\u0644\u0649 \u062a\u0634\u063a\u064a\u0644 \u0648\u0625\u064a\u0642\u0627\u0641 \u0627\u0644\u0636\u0648\u0627\u063a\u0637 \u0644\u062a\u0642\u0644\u064a\u0644 \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0632\u0627\u0626\u062f \u0625\u0644\u0649 \u0623\u062f\u0646\u0649 \u062d\u062f\u060c \u0648\u064a\u062d\u062f\u062f \u0646\u0637\u0627\u0642\u0627\u062a \u0636\u063a\u0637 \u0645\u062a\u0639\u062f\u062f\u0629 \u0644\u062a\u0646\u0627\u0633\u0628 \u0627\u0644\u0638\u0631\u0648\u0641 \u0627\u0644\u0645\u062e\u062a\u0644\u0641\u0629 \u0645\u062b\u0644 \u0633\u0627\u0639\u0627\u062a \u0639\u062f\u0645 \u0627\u0644\u0625\u0646\u062a\u0627\u062c\u060c \u0643\u0645\u0627 \u064a\u0642\u0648\u0645 \u0628\u0636\u0628\u0637 \u0636\u063a\u0637 \u0627\u0644\u0646\u0638\u0627\u0645 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0651\u0627 \u0644\u062a\u0639\u0648\u064a\u0636 \u0627\u0646\u062e\u0641\u0627\u0636\u0627\u062a \u0627\u0644\u0636\u063a\u0637 \u0627\u0644\u0646\u0627\u062a\u062c\u0629 \u0639\u0646 \u0627\u0644\u0645\u0631\u0634\u062d\u0627\u062a \u0648\u0627\u0644\u0623\u0646\u0627\u0628\u064a\u0628 \u0648\u0627\u0644\u0645\u062c\u0641\u0641\u0627\u062a. \u0648\u064a\u0624\u062f\u064a \u062e\u0641\u0636 \u0636\u063a\u0637 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0628\u0645\u0642\u062f\u0627\u0631 1 \u0628\u0627\u0631 \u0625\u0644\u0649 \u062e\u0641\u0636 \u0627\u0633\u062a\u0647\u0644\u0627\u0643 \u0627\u0644\u0637\u0627\u0642\u0629 \u0628\u0646\u0633\u0628\u0629 7 \u0641\u064a \u0627\u0644\u0645\u0627\u0626\u0629 \u0648\u062a\u0633\u0631\u0628\u0627\u062a \u0627\u0644\u0647\u0648\u0627\u0621 \u0628\u0646\u0633\u0628\u0629 13 \u0641\u064a \u0627\u0644\u0645\u0627\u0626\u0629.<\/p>\n<h3>\u062e\u064a\u0627\u0631\u0627\u062a \u062a\u0648\u0633\u0639 \u0646\u0637\u0627\u0642 \u0627\u0644\u062d\u0632\u0645\u0629<\/h3>\n<ul>\n<li>\u0642\u064a\u0627\u0633 \u0646\u0628\u0636\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u0627\u062a \u2014 \u0645\u0631\u0627\u0642\u0628\u0629 \u0645\u0633\u062a\u0645\u0631\u0629 \u0644\u0646\u0628\u0636\u0627\u062a \u0627\u0644\u0635\u062f\u0645\u0627\u062a (SPM) \u0644\u0639\u0646\u0635\u0631 \u0627\u0644\u0636\u0627\u063a\u0637 \u0648\u0645\u062d\u0627\u0645\u0644 \u0627\u0644\u0645\u062d\u0631\u0643\u060c \u0645\u0639 \u0645\u0633\u062a\u0648\u064a\u0627\u062a \u0625\u0646\u0630\u0627\u0631 \u0648\u0625\u064a\u0642\u0627\u0641 \u0645\u0628\u0631\u0645\u062c\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0623\u0648\u0644\u064a\u060c \u0628\u062d\u064a\u062b \u064a\u062a\u0645 \u0625\u062c\u0631\u0627\u0621 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0634\u0627\u0645\u0644\u0629 \u0639\u0646\u062f\u0645\u0627 \u062a\u062a\u0637\u0644\u0628 \u062d\u0627\u0644\u0629 \u0627\u0644\u0645\u062d\u0627\u0645\u0644 \u0630\u0644\u0643.<\/li>\n<li>\u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u064a\u0629 \u0644\u0644\u0645\u062d\u0631\u0643 \u2014 \u062e\u0645\u0633\u0629 \u0645\u0633\u062a\u0634\u0639\u0631\u0627\u062a \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0645\u0646 \u0637\u0631\u0627\u0632 PT-1000 \u0641\u064a \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u060c \u0627\u062b\u0646\u0627\u0646 \u0639\u0644\u0649 \u0627\u0644\u0645\u062d\u0627\u0645\u0644 \u0648\u062b\u0644\u0627\u062b\u0629 \u0641\u064a \u0627\u0644\u0644\u0641\u0627\u062a\u060c \u062a\u064f\u0639\u0631\u0636 \u0642\u064a\u0645\u0647\u0627 \u0639\u0644\u0649 \u062c\u0647\u0627\u0632 \u00ab\u0625\u0644\u0643\u062a\u0631\u0648\u0646\u064a\u0643\u0648\u0646\u00bb \u0645\u0639 \u0625\u0646\u0630\u0627\u0631\u0627\u062a \u0648\u0625\u062c\u0631\u0627\u0621\u0627\u062a \u0625\u064a\u0642\u0627\u0641 \u0645\u0628\u0631\u0645\u062c\u0629 \u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0645\u062d\u0631\u0643.<\/li>\n<li>\u0632\u064a\u062a \u0645\u062e\u0635\u0635 \u0644\u0644\u0627\u0633\u062a\u062e\u062f\u0627\u0645 \u0627\u0644\u063a\u0630\u0627\u0626\u064a \u2014 \u062e\u064a\u0627\u0631 \u0632\u064a\u062a \u00ab\u0631\u0648\u062a\u0648-\u0641\u0648\u062f\u062c\u0631\u064a\u062f\u00bb (Roto-Foodgrade) \u0627\u0644\u0645\u062e\u0635\u0635 \u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u062a\u0639\u0628\u0626\u0629 \u0648\u0627\u0644\u062a\u063a\u0644\u064a\u0641\u060c \u0648\u0627\u0644\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0635\u064a\u062f\u0644\u0627\u0646\u064a\u0629\u060c \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0623\u063a\u0630\u064a\u0629 \u0648\u0627\u0644\u0645\u0634\u0631\u0648\u0628\u0627\u062a\u060c \u062d\u064a\u062b \u064a\u064f\u0633\u0645\u062d \u0628\u0627\u0644\u062a\u0644\u0627\u0645\u0633 \u0627\u0644\u0639\u0631\u0636\u064a \u062f\u0627\u062e\u0644 \u0645\u0646\u0627\u0637\u0642 \u0645\u0639\u0627\u0644\u062c\u0629 \u0627\u0644\u0623\u063a\u0630\u064a\u0629 \u0648\u062d\u0648\u0644\u0647\u0627.<\/li>\n<li>\u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a \u0648\u0627\u0644\u0623\u062f\u0627\u0621 \u2014 \u0632\u064a\u0627\u0631\u0629 \u0627\u0644\u0645\u0635\u0646\u0639 \u0648\u0645\u0631\u0627\u0642\u0628\u0629 \u0627\u062e\u062a\u0628\u0627\u0631 \u0627\u0644\u0623\u062f\u0627\u0621 \u0627\u0644\u0642\u064a\u0627\u0633\u064a \u0648\u0641\u0642\u064b\u0627 \u0644\u0644\u0645\u0639\u064a\u0627\u0631 ISO 1217: 2009\u060c \u0627\u0644\u0645\u0631\u0641\u0642\u0627\u0646 C \u0648 E (\u0627\u0644\u0637\u0628\u0639\u0629 \u0627\u0644\u0631\u0627\u0628\u0639\u0629).<\/li>\n<li>\u0627\u0644\u0646\u0633\u062e\u0629 \u0627\u0644\u0645\u062e\u0635\u0635\u0629 \u0644\u062f\u0631\u062c\u0627\u062a \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u0645\u062d\u064a\u0637\u0629 \u0627\u0644\u0645\u0631\u062a\u0641\u0639\u0629 \u2014 \u062a\u0634\u063a\u064a\u0644 \u0645\u0633\u062a\u0645\u0631 \u0648\u0645\u0648\u062b\u0648\u0642 \u0641\u064a \u0627\u0644\u0645\u0646\u0627\u062e\u0627\u062a \u0627\u0644\u062d\u0627\u0631\u0629 \u0648\u0627\u0644\u0631\u0637\u0628\u0629 \u062d\u062a\u0649 55 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 \u0628\u0627\u0644\u0646\u0633\u0628\u0629 \u0644\u0644\u0648\u062d\u062f\u0629 \u0630\u0627\u062a \u0627\u0644\u0633\u0631\u0639\u0629 \u0627\u0644\u062b\u0627\u0628\u062a\u0629.<\/li>\n<\/ul>\n<figure id=\"attachment_8459\" class=\"wp-caption aligncenter\" style=\"width: 300px;\" aria-describedby=\"caption-attachment-8459\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8459\" src=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-300x300.webp\" alt=\"Atlas Copco GA 200 (1)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-300x300.webp 300w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-150x150.webp 150w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-768x768.webp 768w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-600x600.webp 600w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1-100x100.webp 100w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-1.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-8459\" class=\"wp-caption-text\">Atlas Copco GA 200 (1)<\/figcaption><\/figure>\n<h2>Applications of the GA 200<\/h2>\n<p>Mining operations run the GA 200 for dust bag filtration, service air, ventilation air and pneumatic tools, where reliability and robustness decide the shift plan. Power plants keep a continuous supply of compressed air for soot blowing and fly ash handling, and metal plants use it for instrumentation, plant air and the pneumatic conveying of raw materials or ash.<\/p>\n<p>\u062a\u064f\u0639\u062f \u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0623\u0633\u0645\u0646\u062a \u0645\u0646 \u0623\u0643\u0628\u0631 \u0645\u0633\u062a\u0647\u0644\u0643\u064a \u0627\u0644\u0647\u0648\u0627\u0621 \u0627\u0644\u0645\u0636\u063a\u0648\u0637\u060c \u062d\u064a\u062b \u064a\u064f\u0633\u062a\u0647\u0644\u0643 \u0645\u0639\u0638\u0645 \u0647\u0630\u0627 \u0627\u0644\u0647\u0648\u0627\u0621 \u0641\u064a \u0646\u0642\u0644 \u0627\u0644\u0645\u0648\u0627\u062f \u0627\u0644\u062e\u0627\u0645 \u062f\u0627\u062e\u0644 \u0627\u0644\u0645\u0635\u0646\u0639. \u0648\u0639\u0646\u062f\u0645\u0627 \u064a\u0639\u0645\u0644 \u0627\u0644\u0645\u0635\u0646\u0639 <a href=\"https:\/\/www.compressorpartsmall.com\/ar\/product\/atlas-copco-ga-160-pack-ff\/\">GA 160<\/a> below this class, the GA 200 repeats the same platform logic with 60 kW more installed power, and fluctuating networks pair it with the GA 200 VSD of the same frame. Paper mills and general industry complete the picture with the daily base-load workload of a production hall.<\/p>\n<h2>Service and Support Around the GA 200<\/h2>\n<p>\u064a\u062a\u0645 \u062a\u062c\u0645\u064a\u0639 \u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631 \u0645\u0639\u064b\u0627 \u0644\u062a\u0633\u0647\u064a\u0644 \u0627\u0644\u0648\u0635\u0648\u0644 \u0625\u0644\u064a\u0647\u0627\u060c \u0648\u0642\u062f \u0635\u064f\u0645\u0645\u062a \u062c\u0645\u064a\u0639 \u0627\u0644\u0645\u0643\u0648\u0646\u0627\u062a \u0628\u062d\u064a\u062b \u064a\u0633\u0647\u0644 \u0635\u064a\u0627\u0646\u062a\u0647\u0627\u060c \u0643\u0645\u0627 \u064a\u062a\u064a\u062d \u062a\u0635\u0645\u064a\u0645 \u0627\u0644\u0628\u0648\u0627\u0628\u0629 \u0627\u0644\u062d\u0627\u0626\u0632 \u0639\u0644\u0649 \u0628\u0631\u0627\u0621\u0629 \u0627\u062e\u062a\u0631\u0627\u0639 \u0648\u0635\u0648\u0644\u0627\u064b \u0643\u0627\u0645\u0644\u0627\u064b \u0625\u0644\u0649 \u0643\u0644 \u0645\u0643\u0648\u0646 \u0639\u0646\u062f \u0627\u0644\u062d\u0627\u062c\u0629 \u0625\u0644\u0649 \u0648\u0635\u0648\u0644 \u0623\u0648\u0633\u0639. \u0648\u0642\u062f \u0635\u064f\u0645\u0645 \u0643\u0644 \u0645\u0643\u0648\u0646 \u0647\u0646\u062f\u0633\u064a\u064b\u0651\u0627 \u0644\u062a\u0642\u0644\u064a\u0644 \u0648\u0642\u062a \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0625\u0644\u0649 \u0627\u0644\u0646\u0635\u0641 \u0645\u0642\u0627\u0631\u0646\u0629\u064b \u0628\u0627\u0644\u062a\u0635\u0627\u0645\u064a\u0645 \u0627\u0644\u062a\u0642\u0644\u064a\u062f\u064a\u0629\u060c \u0648\u0644\u0627 \u064a\u062a\u0637\u0644\u0628 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u0628\u0631\u062f \u0628\u0627\u0644\u0632\u064a\u062a \u0623\u064a \u062a\u062f\u062e\u0644\u0627\u062a \u0635\u064a\u0627\u0646\u0629. \u062a\u063a\u0637\u064a \u062e\u0637\u0637 \u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0627\u0644\u0625\u0635\u0644\u0627\u062d\u0627\u062a \u0648\u0627\u0644\u0635\u064a\u0627\u0646\u0629 \u0627\u0644\u0648\u0642\u0627\u0626\u064a\u0629 \u0648\u0642\u0637\u0639 \u0627\u0644\u063a\u064a\u0627\u0631\u060c \u0643\u0645\u0627 \u0623\u0646 \u0633\u0648\u0627\u0626\u0644 \u0648\u0632\u064a\u0648\u062a \u0627\u0644\u062a\u0634\u062d\u064a\u0645 \u0645\u0646 Atlas Copco \u0645\u0635\u0645\u0645\u0629 \u062e\u0635\u064a\u0635\u064b\u0627 \u0644\u0644\u0645\u0639\u062f\u0627\u062a \u0648\u062a\u062d\u062a\u0648\u064a \u0639\u0644\u0649 \u0625\u0636\u0627\u0641\u0627\u062a \u0645\u0642\u0627\u0648\u0645\u0629 \u0644\u0644\u0623\u0643\u0633\u062f\u0629 \u0648\u0645\u0636\u0627\u062f\u0629 \u0644\u0644\u062a\u0643\u0648\u0651\u0646 \u0627\u0644\u0631\u063a\u0648\u064a.<\/p>\n<p>Seadweer supplies genuine Atlas Copco spare parts and service kits for the installed base of the GA 200 and its Full Feature branches. Send us the compressor model together with the parts you need, and the correct items are confirmed with the quotation in one pass.<\/p>\n<figure id=\"attachment_8460\" class=\"wp-caption aligncenter\" style=\"width: 300px;\" aria-describedby=\"caption-attachment-8460\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8460\" src=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-300x300.webp\" alt=\"Atlas Copco GA 200 (2)\" width=\"300\" height=\"300\" srcset=\"https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-300x300.webp 300w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-150x150.webp 150w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-768x768.webp 768w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-600x600.webp 600w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2-100x100.webp 100w, https:\/\/www.compressorpartsmall.com\/wp-content\/uploads\/2026\/10\/Atlas-Copco-GA-200-2.webp 800w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><figcaption id=\"caption-attachment-8460\" class=\"wp-caption-text\">Atlas Copco GA 200 (2)<\/figcaption><\/figure>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<h3>What does the GA 200 deliver at 7.5 bar?<\/h3>\n<p>The 7.5 bar version delivers 729 l\/s at full working pressure, which equals 43.7 m\u00b3\/min or 1,545 cfm. The Full Feature build reads the same flow with a working pressure of 7.3 bar(e) behind the integrated dryer.<\/p>\n<h3>Is the GA 200 an oil-injected machine?<\/h3>\n<p>\u0646\u0639\u0645. \u0625\u0646\u0647 \u0636\u0627\u063a\u0637 \u0644\u0648\u0644\u0628\u064a \u062f\u0648\u0627\u0631 \u064a\u0639\u0645\u0644 \u0628\u0627\u0644\u062d\u0642\u0646 \u0628\u0627\u0644\u0632\u064a\u062a\u060c \u062d\u064a\u062b \u064a\u0639\u0645\u0644 \u0627\u0644\u0632\u064a\u062a \u0639\u0644\u0649 \u0639\u0632\u0644 \u0648\u062a\u0628\u0631\u064a\u062f \u0639\u0646\u0635\u0631 \u0627\u0644\u0636\u063a\u0637 \u0642\u0628\u0644 \u0623\u0646 \u064a\u0642\u0648\u0645 \u0627\u0644\u0641\u0627\u0635\u0644 \u0628\u0625\u0632\u0627\u0644\u062a\u0647 \u0645\u0646 \u062a\u064a\u0627\u0631 \u0627\u0644\u0647\u0648\u0627\u0621. \u0623\u0645\u0627 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u062e\u0627\u0644\u064a \u0645\u0646 \u0627\u0644\u0632\u064a\u062a \u0641\u064a\u0646\u062a\u0645\u064a \u0625\u0644\u0649 \u0645\u0646\u0635\u062a\u064a ZR \u0648ZT \u0627\u0644\u0645\u0646\u0641\u0635\u0644\u062a\u064a\u0646.<\/p>\n<h3>How much heat can the GA 200 recover?<\/h3>\n<p>\u064a\u0633\u062a\u0639\u064a\u062f \u0646\u0638\u0627\u0645 \u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a \u0645\u0627 \u064a\u0635\u0644 \u0625\u0644\u0649 78 \u0641\u064a \u0627\u0644\u0645\u0627\u0626\u0629 \u0645\u0646 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0645\u0648\u0644\u062f\u0629 \u0645\u0646 \u0627\u0644\u0645\u062d\u0631\u0643 \u0627\u0644\u0645\u062f\u0645\u062c \u0648\u062f\u0627\u0626\u0631\u0629 \u0632\u064a\u062a \u0627\u0644\u0639\u0646\u0635\u0631. \u0648\u062a\u062e\u0631\u062c \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0645\u0646 \u0627\u0644\u0648\u062d\u062f\u0629 \u0639\u0644\u0649 \u0634\u0643\u0644 \u0645\u0627\u0621 \u062f\u0627\u0641\u0626 \u0623\u0648 \u0645\u0627\u0621 \u0633\u0627\u062e\u0646 \u0645\u0646 \u0645\u0628\u0627\u062f\u0644 \u062d\u0631\u0627\u0631\u064a \u0645\u0635\u0646\u0648\u0639 \u0645\u0646 \u0627\u0644\u0641\u0648\u0644\u0627\u0630 \u0627\u0644\u0645\u0642\u0627\u0648\u0645 \u0644\u0644\u0635\u062f\u0623.<\/p>\n<h3>What does FF add to the GA 200?<\/h3>\n<p>FF stands for Full Feature: the package integrates a refrigerant dryer with a 3 degrees Celsius pressure dew point and continuous dew point monitoring. The branch adds 630 mm of package length and 600 kg of weight to the air-cooled build.<\/p>\n<h3>How loud is the GA 200?<\/h3>\n<p>The sound pressure level at the work station ranges from 70 to 74 dB(A) across the 50 Hz versions and from 75 to 77 dB(A) across the 60 Hz versions. The value is the A-weighted emission sound pressure level at the work station.<\/p>\n<h3>Which industries run the GA 200?<\/h3>\n<p>\u062a\u0639\u062f \u0642\u0637\u0627\u0639\u0627\u062a \u0627\u0644\u062a\u0639\u062f\u064a\u0646 \u0648\u0645\u062d\u0637\u0627\u062a \u062a\u0648\u0644\u064a\u062f \u0627\u0644\u0637\u0627\u0642\u0629 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0645\u0639\u0627\u062f\u0646 \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0623\u0633\u0645\u0646\u062a \u0648\u0645\u0635\u0627\u0646\u0639 \u0627\u0644\u0648\u0631\u0642 \u0645\u0646 \u0623\u0643\u0628\u0631 \u0645\u0633\u062a\u062e\u062f\u0645\u064a \u0647\u0630\u0647 \u0627\u0644\u0623\u0646\u0638\u0645\u0629\u060c \u0628\u064a\u0646\u0645\u0627 \u062a\u0634\u0643\u0644 \u0627\u0644\u0635\u0646\u0627\u0639\u0629 \u0627\u0644\u0639\u0627\u0645\u0629 \u0627\u0644\u062c\u0632\u0621 \u0627\u0644\u0645\u062a\u0628\u0642\u064a \u0645\u0646 \u0642\u0627\u0639\u062f\u0629 \u0627\u0644\u0645\u0633\u062a\u062e\u062f\u0645\u064a\u0646. \u0648\u062a\u0642\u062f\u0651\u0631 \u062c\u0645\u064a\u0639 \u0647\u0630\u0647 \u0627\u0644\u0642\u0637\u0627\u0639\u0627\u062a \u0646\u0638\u0627\u0645 \u0646\u0642\u0644 \u0627\u0644\u062d\u0631\u0643\u0629 \u0628\u0645\u0639\u064a\u0627\u0631 IP66\u060c \u0648\u0627\u0644\u062a\u062d\u0643\u0645 \u0627\u0644\u062b\u0627\u0628\u062a \u0641\u064a \u0627\u0644\u062d\u0645\u0644 \u0627\u0644\u0623\u0633\u0627\u0633\u064a\u060c \u0648\u062e\u064a\u0627\u0631 \u0627\u0633\u062a\u0639\u0627\u062f\u0629 \u0627\u0644\u062d\u0631\u0627\u0631\u0629 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631.<\/p>","protected":false},"excerpt":{"rendered":"<p>The Atlas Copco GA 200 is the 220 kW fixed-speed oil-injected rotary screw compressor of the GA 180-315 platform, delivering 624 to 833 l\/s across the 5.5, 7.5, 8.5 and 10 bar versions in 50 Hz and the 75 to 150 psi versions in 60 Hz. The Full Feature branch integrates a refrigerant dryer with a 3 degrees Celsius dew point, and the drive train carries an IP66 rating for the harshest plants. For a quotation on the GA 200, send us your compressor requirements and Seadweer confirms the configuration with the offer.<\/p>","protected":false},"featured_media":8456,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[3692],"product_cat":[3834],"product_tag":[3835],"class_list":["post-8463","product","type-product","status-publish","has-post-thumbnail","product_brand-atlas-copco","product_cat-oil-injected","product_tag-oil-injected-air-compressors","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/product\/8463","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/comments?post=8463"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/media\/8456"}],"wp:attachment":[{"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/media?parent=8463"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/product_brand?post=8463"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/product_cat?post=8463"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.compressorpartsmall.com\/ar\/wp-json\/wp\/v2\/product_tag?post=8463"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}