Descripción
El 1089062404 is the Atlas Copco solenoid valve 110V 50/60HZ 10BAR, an electrical pilot valve for the unloader circuit that is recorded in the official parts lists of the oil-injected GA screw compressor range. In those lists it appears under item position 1 020 with the name Solenoid valve, quantity 1, and it is one of the parts a GA machine calls on whenever the unloader side of the package needs a directed air signal from the 1089062404.
This page follows the 1089062404 through the four parts list documents that record it, the neighbouring hardware that sits beside it on the same page, and the practical points a planner handles when the order is placed.
What the 1089062404 Is
The designation on the record is written out fully as SOLENOID VALVE 110V 50/60HZ 10BAR, and each element of that string carries information the installer uses. The 110V figure is the coil voltage the part is wound for, the 50/60HZ marking covers both supply frequencies used across markets, and 10BAR states the pressure class the valve body of the 1089062404 is built around.
The recorded weight of the part is 1.925 kg with dimensions of 210 x 110 x 110 mm, and the official page lists Germany as the country of origin.
Each element of the designation is read from the record, never guessed.
Inside the GA package, a solenoid valve of this class such as the 1089062404 is the electrical switch that routes a pneumatic signal when the controller calls for it.
Because the action is driven by the coil rather than by machine pressure alone, the valve answers the controller directly, which is why the parts lists group it with the electrical accessories of the compressor rather than with the air-end hardware.

Documented Machine Coverage
El 1089062404 is recorded across four separate Atlas Copco parts list documents, and each of them names the same item number in the same role. The first is the parts list of the GA 30+, GA 37 and GA 45 compressors, where the entry reads 1089 0624 04, quantity 1, Solenoid valve, and where the same page continues with the cable gland 0698 5140 71 and the lock nut 0697 9809 20 as the electrical accessories that follow it.
The second document is the parts list of a GA30 machine with the serial number prefix API542595, which lists 1089 0624 04, quantity 1, SOLENOID VALVE, with the date range 30/03/2012 onwards, and which marks the accompanying seal as position 1025, item 0663 2107 81, quantity 1, O-RING.
The third is the parts list of the GA 55, GA 55+, GA 75, GA 75+ and GA 90, published by Atlas Copco Airpower n.v. of Antwerp, Belgium.
Its entry is position 1 020, item 1089 0624 04, quantity 1, Solenoid valve, next to position 1 025, the O-ring 0663 2107 81, and position 1 030, the Nipple 1625 4040 00. The fourth is the 2020 parts list of the GA 55 VSD, GA 75 VSD and GA 90 VSD, where item position 1 020 again corresponds to the 1089062404.
The identity of the item is therefore stable across every document that names it.
Read together, the four documents cover both the smaller fixed-speed frames of the range and the larger frames in both fixed-speed and VSD form, so the machine families the part serves include GA 30+, GA 37, GA 45, GA 30, GA 55, GA 55+, GA 75, GA 75+, GA 90 and the VSD versions of the 55, 75 and 90 frames.

The 110V and 220V Electrical Configurations
The page of the GA 55 to GA 90 parts list carries an explicit note that distinguishes between 110V and 220V electrical configurations of the package, and this distinction matters at ordering time for the 1089062404. The 1089062404 is the 110V winding of the solenoid valve.
A machine ordered with the 220V configuration takes a different coil voltage on the same function. Matching the coil voltage to the configuration the machine was built with is the one electrical check that prevents a valve that fits mechanically but does not pull in on the supply the controller provides.
Because the coil covers both 50 and 60 HZ supply frequencies, the voltage match is the only electrical parameter that needs confirming. The 10BAR pressure class covers the signal pressures the unloader circuit of these GA frames works at.
Parts That Sit Beside It on the Lists
The parts list pages place four neighbours around the 1089062404, and each has its own item number. The O-ring 0663 2107 81 is recorded as the accompanying seal, and it is the part renewed whenever the valve is removed and refitted, because a reused O-ring at this seat is the common cause of a slow signal leak after the work is done. The Nipple 1625 4040 00 is the connection piece recorded at position 1 030 that carries the pneumatic lines to and from the valve body.
On the GA 30+, GA 37 and GA 45 page, the cable gland 0698 5140 71 and the lock nut 0697 9809 20 follow the valve in the list, and they are the parts that terminate the coil cable where it enters the valve housing. These four neighbouring numbers are recorded here exactly as the official lists print them, and they are the natural companions to check for whenever the valve itself is being ordered.

Installation and Replacement Practice
The replacement work at the position of the 1089062404 is short and electrical in character. The supply to the coil of the 1089062404 is isolated and proved dead, the coil connections are opened at the cable gland, and the valve is unscrewed from its pneumatic ports. The O-ring 0663 2107 81 is fitted new at the seat, the valve is refitted, and the nipple side is reconnected before the cable is terminated through the gland and the lock nut closes the entry.
After refitting, the controller command is exercised and the valve response is observed at the signal side, which confirms the coil pulls in and releases as the controller expects. A 1089062404 that fails to respond to the controller command, or one that chatters at the seat, is the part the log entry describes, and the entry is what turns the observation into a planned order rather than an unplanned stop.

Ordering the 1089062404
The parts lists of the GA range print the item as 1089 0624 04, which is the same number as the 1089062404 written without spacing, so either form identifies the same part when a quote is requested from Seadweer. The machine model and serial number are the reference that confirms the electrical configuration of the package that takes the 1089062404, because the 110V and 220V options share the same mechanical position.
The coil voltage is the detail the parts list note exists to settle.
Seadweer supplies the 1089062404 as a genuine Atlas Copco part, with the recorded origin of Germany and the recorded pressure class of 10BAR. The packing is a wooden case sized for the valve, delivery takes 7-14 business days, and the payment and shipping options are listed beside the price on the product page.
Summary
El 1089062404 is the solenoid valve 110V 50/60HZ 10BAR of the oil-injected GA screw compressor range, recorded at position 1 020 in four official parts list documents that together cover the GA 30+ to GA 90 frames in both fixed-speed and VSD form. Its neighbours on those pages are the parts to review alongside the 1089062404: the O-ring 0663 2107 81, the Nipple 1625 4040 00, the cable gland 0698 5140 71 and the lock nut 0697 9809 20.
The coil voltage is the one check that settles the 110V against the 220V configuration of the machine it serves. and the coil voltage is the one check that settles the 110V against the 220V configuration of the machine it serves.
| Especificaciones | Valor |
|---|---|
| Número de referencia | 1089062404 |
| Official designation | SOLENOID VALVE 110V 50/60HZ 10BAR |
| Parts list name | Válvula solenoide |
| Parts list position | 1 020 |
| Coil voltage | 110V, 50/60HZ |
| Pressure class | 10 BAR |
| Item weight | 1.925 kg |
| Item dimensions (L x W x H) | 210 x 110 x 110 mm |
| País de origen | DE (Germany) |
| Código arancelario | 84818059 |
| Documented machines | GA 30+, GA 37, GA 45, GA 30 (API542595), GA 55, GA 55+, GA 75, GA 75+, GA 90, GA 55/75/90 VSD |
| Accompanying seal | 0663 2107 81 O-RING |
| Pipe connection | 1625 4040 00 Nipple |
| Electrical accessories | 0698 5140 71 cable gland, 0697 9809 20 lock nut |
| Categoría | S4B Valve |

Preguntas frecuentes
Which machines does the 1089062404 fit?
The official parts list documents record the 1089062404 for the GA 30+, GA 37 and GA 45, for a GA30 with serial prefix API542595, for the GA 55, GA 55+, GA 75, GA 75+ and GA 90, and for the GA 55 VSD, GA 75 VSD and GA 90 VSD in the 2020 list.
What does the 110V 50/60HZ 10BAR marking mean?
For the 1089062404, 110V is the coil voltage, 50/60HZ means the coil accepts both supply frequencies, and 10BAR is the pressure class of the valve body.
Is there a 220V version of the same valve?
The parts list page carries a note distinguishing 110V and 220V electrical configurations of the package, so the machine configuration decides which coil voltage the position takes; this page covers the 110V part.
Which seal is renewed when the valve is replaced?
The O-ring 0663 2107 81, recorded at position 1 025 beside the 1089062404, is the accompanying seal and is fitted new at every removal.
Where is the item printed in the parts lists?
The lists print the item as 1089 0624 04 at position 1 020 with quantity 1, which is the same number as the 1089062404 written without spacing.
More Atlas Copco Valves Available
Further Atlas Copco valves can be supplied on request. Have a look at the table below, or get in touch with us for more information.
| Número de referencia | Nombre de la pieza | Número de referencia |
|---|---|---|
| 0832100045 | VALVE-SAFETY | 0832-1000-45 |
| 0832100048 | VALVE-SAFETY | 0832-1000-48 |
| 0832100050 | VALVE-SAFETY-FILME COMPRESSOR | 0832-1000-50 |
| 0832100053 | SAFETY VALVE | 0832-1000-53 |
| 0832100055 | VALVE-SAFETY | 0832-1000-55 |
| 0832100056 | VALVE-SAFETY | 0832-1000-56 |
| 0832100058 | SAFETY VALVE | 0832-1000-58 |
| 0832100059 | SAFETY VALVE | 0832-1000-59 |
| 0832100060 | VALVE-SAFETY | 0832-1000-60 |
| 0832100063 | VALVE-SAFETY | 0832-1000-63 |
| 0832100064 | VALVE-SAFETY-FILME COMPRESSOR | 0832-1000-64 |
| 0832100070 | VALVE-SAFETY-FILME COMPRESSOR | 0832-1000-70 |
| 0832100072 | VALVE-SAFETY | 0832-1000-72 |
| 0832100074 | VALVE-SAFETY | 0832-1000-74 |
| 0832100077 | VALVE-SAFETY | 0832-1000-77 |
| 0832100078 | VALVE-SAFETY | 0832-1000-78 |
| 0832100079 | VALVE-SAFETY | 0832-1000-79 |
| 0832100083 | VALVE-SAFETY | 0832-1000-83 |
| 0832100089 | VALVE-SAFETY | 0832-1000-89 |
| 0832100092 | SAFETY VALVE | 0832-1000-92 |
| 0832100107 | SAFETY VALVE | 0832-1001-07 |
| 0832100108 | VALVE-SAFETY | 0832-1001-08 |
| 0832100109 | SAFETY VALVE | 0832-1001-09 |
| 0832100110 | VALVE-SAFETY | 0832-1001-10 |
| 0832100111 | VALVE-SAFETY | 0832-1001-11 |
| 0832100112 | VALVE-SAFETY | 0832-1001-12 |
| 0832100113 | VALVE-SAFETY | 0832-1001-13 |
| 0832100114 | VALVE-SAFETY-FILME COMPRESSOR | 0832-1001-14 |
| 0832100116 | VALVE-SAFETY | 0832-1001-16 |
| 0832100117 | VALVE-SAFETY | 0832-1001-17 |
| 0832100118 | SAFETY VALVE | 0832-1001-18 |
| 0832100119 | VALVE-SAFETY | 0832-1001-19 |
| 0832100122 | SAFETY VALVE | 0832-1001-22 |
| 0832100127 | SAFETY VALVE | 0832-1001-27 |
| 0832100128 | VALVE-SAFETY | 0832-1001-28 |
| 0832100130 | SAFETY VALVE | 0832-1001-30 |
| 0832100137 | SAFETY VALVE | 0832-1001-37 |
| 0832100138 | SAFTEY-VALVE | 0832-1001-38 |
| 0832100142 | SAFETY VALVE AS | 0832-1001-42 |
| 0832100144 | SAFETY VALVE AS | 0832-1001-44 |
| 0832100150 | SAFETY VALVE ASME AP | 0832-1001-50 |
| 0832100151 | SAFTEY-VALVE | 0832-1001-51 |
| 0832100163 | SAFETY VALVE | 0832-1001-63 |
| 0832100169 | SAFETY VALVE | 0832-1001-69 |
| 0832100171 | SAFETY VALVE | 0832-1001-71 |
| 0832100172 | SAFETY VALVE | 0832-1001-72 |
| 0832100173 | SAFETY VALVE | 0832-1001-73 |
| 0832100182 | SAFETY VALVE | 0832-1001-82 |
| 0832100191 | SAFETY VALVE | 0832-1001-91 |
| 0832100193 | SAFETY VALVE | 0832-1001-93 |















Wim Vandenbroucke –
We ordered the 1089062404 against the model and serial number of our GA 75 after the controller started logging a fault at the unloader signal side. The valve arrived from Germany packed well, and the 110V coil rating and the 10 BAR marking on the body matched the record in the machine file. The O-ring went in new with the valve, and the controller command was answered from the first restart. The replacement is logged with the service date for the next round.