Descripción
The 1089050240 is the temperature indicator switch fitted to Atlas Copco portable compressor builds in the OR series. The shop record lists the part as SWITCH, and the printed ORX 12 parts book positions the same number at item 250 under the name TEMP. INDICATOR. One unit covers a stage discharge temperature reading on the panel, and the contact behind the dial opens the machine down when the temperature at the probe passes the set limit.
For a portable build that works far from a workshop, this single instrument carries two duties at once. The dial gives the operator a live reading, and the switch contact stops the machine before overheated stages damage the compression elements or the oil. The official documentation assigns the 1089050240 a quantity of two per machine, so each unit guards one stage of the train under the same protection.
Especificaciones técnicas
The data below is taken from the official shop listing for 1089050240 and from the ORX 12 – Parts List for Portable Compressors published by Atlas Copco Airpower of Antwerp, Belgium. Values are reproduced as printed in those sources.
| Número de referencia | 1089050240 |
| Listed description | SWITCH |
| Parts list position | Pos. 250, TEMP. INDICATOR |
| Reference price | 682.25 GBP |
| Origen | DE (Germany) |
| Código arancelario | 90251900 |
| Length x width x height | 360 x 120 x 120 mm |
| Peso | 420 gr |
| Measuring points per machine | 2 (first and second stage discharge) |
| Companion seal in the parts list | Pos. 260, FLAT GASKET 0653 1124 00, quantity 2 |

One Instrument, Two Jobs on the Panel
Most panel instruments do a single job: a gauge reads, a lamp signals, a relay switches. The 1089050240 does two jobs at once, which is why the parts book names it an indicator and the shop lists it as a switch. The dial of the 1089050240 shows the operator a live temperature reading for the compression stages against a printed black face. Behind that dial an electrical contact changes state at the set point.
That contact is wired into the shutdown path of the machine. On a drilling site the panel is not always watched, so a rising temperature has to act on its own rather than wait for an operator to see it. With the 1089050240 in the circuit, the same rising temperature that moves the needle also stops the machine. Each of the two stage positions is guarded by its own unit of the same type.
Capillary Dial, Probe and Panel Flange
The photographs show the construction behind the specification figures. The dial sits in a stainless case with a front bezel and a flanged rim, and the flange carries the fixings that hold the instrument in the panel cut-out. The face is black with a printed scale, so the reading stays legible in dust and glare on a site. A red marker on the case is used to set the alarm position against the scale.
Between the case and the measuring point runs a fine capillary line. Armour spring sections protect the line where it can be touched or caught, and the line ends in a threaded probe with a hex fitting that screws into the stage discharge pocket. The probe sits in the hot gas stream and the capillary carries the measurement back to the movement behind the dial of the 1089050240. The 360 mm figure in the specification is driven by the probe assembly rather than by the dial alone.
The 420 gr weight of the 1089050240 reflects the stainless case and the probe hardware rather than the dial face. The flanged rim spreads the clamping load over the panel, so the case does not depend on the capillary line for support. That layout keeps the reading stable even when the line is moved during panel service.

Two Stage Positions and the Flat Gasket
The ORX 12 parts list entry defines how the instrument is applied on the machine. Under position 250, the number appears as 1089 0502 40 with a quantity of two, serving the first and the second stage discharge. The printed form 1089 0502 40 in the book and the continuous form 1089050240 in the shop record are the same number written in the two formats Atlas Copco uses across its documentation.
Directly below the instrument, position 260 lists a flat gasket under number 0653 1124 00 with a quantity of two, one seal for each measuring point. The gasket seats between the probe fitting and the discharge pocket. It is a single-use sealing part: once the probe has been removed, the joint needs a new gasket to seal again. Ordering the 1089050240 without the pair of flat gaskets leaves the installation half specified, and the two positions sit next to each other in the book.

Machines Covered in the OR Series
The shop listing ties the part to the portable range built around the OR series and the ORX 12 box configurations. The official designations connected to this instrumentation include OAV4 APP, OR 750-25, OR 700-30, OR 700-35 and the ORX12 BOX builds in standard, NO and NO CANOPY variants. These designations describe the same family of portable units in slightly different record formats. Fitment of 1089050240 is therefore confirmed against the number on the old instrument and the machine serial rather than against the designation text alone.
The instrumentation layout across these builds follows the pattern used for other portable compressors. Panel instruments sit grouped behind the operator position, capillary lines run with armour protection, and discharge probes enter each stage. Because the 1089050240 is applied in pairs, a machine with one failed dial has often been running on its twin at the other stage. Both positions deserve a check during the same service stop.
Checking Fitment Before Ordering
The cross-check before ordering is straightforward. Read the number from the old dial case or from the machine parts book and compare it with 1089050240, allowing for the spaced printing format used in the book. Confirm that the failed unit is the capillary type with a panel flange, not a direct-mount stem type. The probe length, the hex fitting thread and the capillary routing of 1089050240 are shown in the photographs on this page.
The working condition of the old unit tells you what to expect after replacement. An instrument whose needle sat outside the normal band while the machine ran cool points to the instrument itself. A machine that tripped on overtemperature repeatedly before the reading failed points to a real thermal fault upstream. The new 1089050240 shows that fault honestly from the first start-up, without the drift of the worn unit.

Installing the Replacement
Fitment is a panel-side job with the machine isolated. Open the panel, note the capillary routing of the old instrument, and remove the probe from each discharge pocket in turn. Each removal consumes the flat gasket behind it, so fit the two 0653 1124 00 seals from the parts list on reassembly. Screw the probes of the new 1089050240 in to the same depth as the old ones.
Route the capillary line clear of hot and moving parts, with the armour sections placed where the line can be touched. Seat the flange of the 1089050240 into the panel cut-out and tighten the fixings evenly. At start-up, watch both dials climb as the machine loads and confirm that each reading settles in the band the machine documentation gives for that stage. Test the shutdown contact at a controlled moment rather than during a real fault.
Preguntas frecuentes
Why do the sources print two names for this part?
The shop record lists 1089050240 as SWITCH, and the ORX 12 parts list places the same number at position 250 under the name TEMP. INDICATOR. The instrument performs both roles: it shows the stage temperature on the dial and it opens the shutdown contact at the set limit.
Why does the parts list show a quantity of two?
The machine carries one instrument for the first stage discharge and one for the second stage discharge. Each unit reads its own stage, and each probe joint is sealed with its own flat gasket from position 260.
Which gasket fits the probe of 1089050240?
The parts list assigns the flat gasket 0653 1124 00 to the two measuring points of the 1089050240. The gasket is a single-use part, so a new pair is needed each time the probes are removed.
Which machines use this instrument?
The part is listed for the portable OR series builds recorded as OAV4 APP, OR 750-25, OR 700-30, OR 700-35 and the ORX12 BOX variants. Each of these machines takes the 1089050240 at both stage positions. The parts book for the machine serial is the final fitment reference.
How is the dial reading taken on site?
The photographs show a black dial with a printed temperature scale. Read the needle against the band stated in the machine documentation for the stage being checked. The band position in the documentation is set for the machine, not for the dial alone.

Suministro original de Atlas Copco a través de Seadweer
Seadweer supplies the 1089050240 as a genuine Atlas Copco part, packed and labelled by the factory. The listing on this page carries the official specification data, photographs of the supplied instrument, and the parts list references a service team needs for ordering. Both units required for a two-stage machine can be ordered as a pair so the 1089050240 set matches the parts list quantities. Orders ship worldwide, and fitment questions about the OR series instrumentation can be raised with the Seadweer team before purchase.
More Indicators We Can Supply
Further Atlas Copco indicators can be supplied on request. Have a look at the table below, or get in touch with us for more information.
| Número de referencia | Nombre de la pieza | Número de referencia |
|---|---|---|
| 1089026335 | INDICATION LAMP | 1089-0263-35 |
| 1089026337 | INDICATION LAMP | 1089-0263-37 |
| 1089026339 | INDICATION LAMP | 1089-0263-39 |
| 1089050241 | INDICATOR TEMP. | 1089-0502-41 |
| 1089050242 | INDICATOR TEMP. | 1089-0502-42 |
| 1089057767 | INDICATOR | 1089-0577-67 |
| 1089063021 | INDICATOR-TEMP | 1089-0630-21 |
| 1089064921 | LIGHT INDICATOR | 1089-0649-21 |
| 1089064922 | LIGHT INDICATOR | 1089-0649-22 |
| 1089064923 | LIGHT INDICATOR | 1089-0649-23 |
| 1089907655 | INDICATOR | 1089-9076-55 |
| 1089923911 | TEMP. INDICATOR | 1089-9239-11 |
| 1089928824 | INDICATING LAMP | 1089-9288-24 |
| 1089951392 | LIGHT INDICATIOR | 1089-9513-92 |
| 1089951394 | LIGHT INDICATIOR | 1089-9513-94 |
| 1089951397 | LIGHT INDICATIOR | 1089-9513-97 |
| 1089952408 | INDICATOR TEMPERATURE | 1089-9524-08 |
| 1089962207 | INDICATOR LIGHT | 1089-9622-07 |
| 1091045102 | INDICATOR | 1091-0451-02 |
| 1092001123 | INDICATOR LIGHT | 1092-0011-23 |
| 1092065601 | INDICATOR | 1092-0656-01 |
| 1202235500 | INDICATOR | 1202-2355-00 |
| 1310255857 | INDICATOR | 1310-2558-57 |
| 1503327335 | INDICATOR | 1503-3273-35 |
| 1504221538 | INDICATOR TEMP. | 1504-2215-38 |
| 1504221539 | INDICATOR TEMP. | 1504-2215-39 |
| 1604026281 | INDICATOR ASY | 1604-0262-81 |
| 1613826400 | MOISTURE INDICATOR | 1613-8264-00 |
| 1617605900 | INDICATOR | 1617-6059-00 |
| 1617704800 | DIFF.PRESSURE INDICATOR | 1617-7048-00 |
| 1617728200 | FLOW INDICATOR (IN TO OUT) | 1617-7282-00 |
| 1617728300 | FLOW INDICATOR (OUT TO IN) | 1617-7283-00 |
| 1617728500 | FLOW INDICATOR (OUT TO IN) | 1617-7285-00 |
| 1619014900 | INDICATOR | 1619-0149-00 |
| 1619227300 | INDICATOR | 1619-2273-00 |
| 1619379005 | INDICATOR | 1619-3790-05 |
| 1619519900 | INDICATOR | 1619-5199-00 |
| 1621346200 | INDICATOR FLOW | 1621-3462-00 |
| 1621505262 | TEMP. INDICATOR | 1621-5052-62 |
| 1621505263 | TEMP. INDICATOR | 1621-5052-63 |
| 1621505646 | INDICATOR | 1621-5056-46 |
| 1621595600 | INDICATOR | 1621-5956-00 |
| 1622223402 | FLOW INDICATOR | 1622-2234-02 |
| 1622223403 | FLOW INDICATOR | 1622-2234-03 |
| 1622223404 | INDICATOR | 1622-2234-04 |
| 1622223405 | FLOW INDICATOR | 1622-2234-05 |
| 1622243200 | TEMP. INDICATOR | 1622-2432-00 |
| 1622621300 | INDICATOR | 1622-6213-00 |
| 1622621304 | INDICATOR MB | 1622-6213-04 |
| 1623469600 | INDICATOR | 1623-4696-00 |















Kris De Vos –
One dial on our ORX 12 box build kept drifting off scale, so we replaced both stage instruments in one stop. The 1089050240 arrived in the original Atlas Copco packaging with the printed number matching the old case. The flange went back into the same panel cut-out and the probes took the new flat gaskets from the parts list. Both stage readings now sit in the normal band and the shutdown contact behaves as documented.