Descripción
Where the ZR 315 VSD Sits in the Oil-Free Range
The ZR 315 VSD is the upper step of the ZR/ZT 200-355 VSD+ platform, the oil-free line that Atlas Copco builds for plants whose compressed air demand has grown past the 110-160 class and now needs the high flow of the 200-355 bracket.
Two 160 kW drive modules give the ZR 315 VSD its 315 kW of installed power. The water-cooled machines of the line below this range are covered by the ZR 250 VSD, and the 355 kW unit sits one step above. The VSD+ control turns both modules across a turn-down window that reaches down to 11% of full speed.
The platform shares one body design from 200 to 355 kW, so a plant that installs the 315 kW step keeps the same layout, the same service concept and the same spare parts logic as the smaller and larger machines around it.
The VSD+ control of the ZR 315 VSD also reads the demand of the network directly.
The letter Z of the ZR 315 VSD marks the oil-free architecture of the range. The compression elements never inject oil into the air stream, so the delivered air carries no added oil and the ZR 315 VSD fits food, pharmaceutical, electronics and textile processes that audit their air supply. The R marks the water-cooled branch: cooling water takes the heat out of the oil circuit, the compressor elements and the motor jackets, which keeps the package compact and stable in warm plant rooms.
Mínimo, efectivo y máximo
The VSD+ concept drives the motor between a minimum, an effective and a maximum pressure setting, and the rated data lists a flow band for each of the three. At the minimum setting of 4 bar(e) the ZR 315 VSD produces 210 to 974 l/s (12.6 to 58.5 m3/min), at the effective setting of 7 bar(e) it produces the same 210 to 974 l/s (12.6 to 58.5 m3/min), and at the maximum of 10.4 bar(e) it still delivers 208 to 838 l/s (12.5 to 50.3 m3/min).
Una planta que adapta el tamaño de su red al punto de funcionamiento óptimo puede funcionar de forma silenciosa, lenta y eficiente durante los turnos de noche, para luego permitir que el motor alcance su velocidad máxima cuando se produzca la carga diurna.
These three bands come from one machine. The ZR 315 VSD does not change its gearing between the settings; the drive simply moves the two modules across their speed window, and the rated flow follows.

Technical Specifications of the ZR 315 VSD
Las cifras que figuran a continuación se han extraído de los datos técnicos oficiales del ZR/ZT 200-355 VSD+. El rendimiento de la unidad se mide según la norma ISO 1217, anexo E, edición 4 (2009), con las condiciones de referencia de humedad relativa 0%, presión absoluta de entrada de 1 bar y temperatura de entrada de 20 °C. El caudal de aire libre se mide a la presión de trabajo efectiva.
Datos nominales del equipo VSD+
La configuración «Pack» integra el compresor, el tren de engranajes, el sistema de accionamiento y los controles en una única carcasa de 3044 mm de longitud, 1760 mm de anchura y 2150 mm de altura. En la tabla se indican los tres rangos de presión para una alimentación de 50 Hz.
| Modelo | Presión de trabajo (bar(e)) | FAD l/s | FAD m³/min | Potencia instalada (kW) | Especificaciones del motor | Nivel de ruido en dB(A) | Peso (kg) |
|---|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 4 | 210 – 974 | 12.6 – 58.5 | 315 | 2 x 160 | 73 | 5439 |
| 7 | 210 – 974 | 12.6 – 58.5 | |||||
| 10.4 | 208 – 838 | 12.5 – 50.3 |
En el caso de las instalaciones con una alimentación de 60 Hz, el mismo Pack tiene las siguientes características nominales.
| Modelo | Presión de trabajo (psig) | FAD l/s | FAD cfm | Potencia instalada (hp) | Especificaciones del motor | Nivel de ruido en dB(A) | Peso en libras |
|---|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 58 | 210 – 974 | 445 – 2064 | 422 | 2 x 215 | 73 | 11991 |
| 100 | 210 – 974 | 445 – 2064 | |||||
| 150 | 208 – 838 | 441 – 1775 |
The A-weighted emission sound pressure level at the work station is measured according to ISO 2151:2008 with the sound intensity scanning method of ISO 9614-2, and the published value carries the total uncertainty of +/- 3 dB(A). At 73 dB(A) the ZR 315 VSD stays inside the sound level of a normal industrial hall, so the ZR 315 VSD can stand on the production floor without a dedicated compressor room.
Datos nominales de la versión iMD con todas las funciones
La versión «Full Feature» incorpora el secador iMD integrado, una unidad de calor de compresión a base de agua que seca el aire del interior del grupo compresor. Dado que el secador funciona con el calor que ya genera el proceso, la banda FAD se desplaza a los valores nominales que se indican a continuación.
| Modelo | Presión de trabajo (bar(e)) | FAD l/s | FAD m³/min | Potencia instalada (kW) | Especificaciones del motor | Nivel de ruido en dB(A) | Peso (kg) |
|---|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 6 | 306 – 960 | 18.4 – 57.6 | 315 | 2 x 160 | 73 | 6730 |
| 7 | 306 – 960 | 18.4 – 57.6 | |||||
| 10.4 | 304 – 830 | 18.2 – 49.8 |
Con una alimentación de 60 Hz, la configuración «Full Feature» de iMD es la siguiente.
| Modelo | Presión de trabajo (psig) | FAD l/s | FAD cfm | Potencia instalada (hp) | Especificaciones del motor | Nivel de ruido en dB(A) | Peso en libras |
|---|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 87 | 306 – 960 | 648 – 2033 | 422 | 2 x 215 | 73 | 14837 |
| 102 | 306 – 960 | 648 – 2033 | |||||
| 151 | 304 – 830 | 644 – 1758 |
Datos nominales del paquete iMDG Split
El modelo iMDG divide el concepto «Full Feature» en dos paquetes diseñados específicamente: el «Compressor Pack» y el secador de tambor, que constituye una unidad independiente en el suelo. Los datos nominales de este concepto dividido son los siguientes.
| Modelo | Presión de trabajo (bar(e)) | FAD l/s | FAD m³/min | Potencia del motor instalado, en kW | Nivel de ruido en dB(A) | Peso (kg) |
|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 6 | 209 – 960 | 12.5 – 57.6 | 315 | 73 | Lote: 4979 Secador iMDG: 2530 |
| 7 | 209 – 960 | 12.5 – 57.6 | ||||
| 10.4 | 208 – 830 | 12.5 – 49.8 |
Para la alimentación a 60 Hz, los datos del iMDG son los siguientes.
| Modelo | Presión de trabajo (psig) | FAD l/s | FAD cfm | Potencia del motor instalado (hp) | Nivel de ruido en dB(A) | Peso en libras |
|---|---|---|---|---|---|---|
| ZR 315 VSD+ 10.4 | 87 | 209 – 960 | 443 – 2033 | 422 | 73 | Referencia: 10977 Secador iMDG: 5578 |
| 102 | 209 – 960 | 443 – 2033 | ||||
| 151 | 208 – 830 | 441 – 1758 |
El conjunto del secador de tambor del modelo iMDG mide 5.651 mm de longitud, 1.927 mm de anchura y 2.150 mm de altura. La división en dos conjuntos permite a la planta ubicar el secador donde lo requiera la red de aire, lo que acorta las tuberías entre el secador y el punto de uso y deja libre la distribución de la sala de compresores para facilitar el acceso de mantenimiento.
Dimensiones y peso
Across the 200-355 platform the Pack body keeps one footprint, and the rated weight of the ZR Pack stands at 5439 kg (11991 lb). The Full Feature iMD package adds the dryer internals inside the same enclosure and reads 6730 kg (14837 lb). A plant planning its floor can reserve one bay for the Pack and, in the iMDG concept, a second bay for the drum dryer package.
Dos unidades NEOS sin pérdidas por descarga
The ZR 315 VSD carries two NEOS drive bodies, each coupled to its own 160 kW permanent magnet motor, and the VSD+ control splits the work between them across the speed window. Between 11% and 100% of speed the machine changes its flow with the demand of the plant, so the blow-off and idle phases that burn energy on fixed-speed machines simply do not appear in the duty cycle. At part load each element runs well inside its rating.
La configuración de doble accionamiento distribuye la carga mecánica: cada elemento funciona a una fracción menor de su potencia nominal, lo que reduce el ruido, el desgaste y la temperatura a carga parcial.
El rango de velocidades del motor del concepto VSD+ mantiene la separación de aceite y la función de secado dentro de sus rangos de funcionamiento, mientras que el caudal se adapta a la demanda. El controlador Elektronikon coordina los dos módulos, y los ejes de transmisión, los engranajes y los cojinetes de los cuerpos NEOS están dimensionados para un funcionamiento continuo en el ciclo sin aceite.

La refrigeración por agua y el recorrido del aire en dos etapas
Air enters the ZR 315 VSD through the inlet filter and passes the first compression stage, which lifts the pressure to an intermediate level. The pulsation dampener steadies the flow before the intercooler, the automated moisture separation removes the condensate, and the second stage brings the air to its final pressure with the efficiency that two-stage compression gives over a single stage at these ratios.
El agua de refrigeración abastece a tres circuitos. Un circuito alimenta el intercooler y el posenfriador que acondicionan el aire comprimido. Un segundo circuito estabiliza la temperatura del aceite de los engranajes y los cojinetes. El tercer circuito recorre las camisas de los motores y los elementos para mantener su temperatura de funcionamiento.
The oil loop of the ZR 315 VSD itself pumps cooled oil through a high efficiency filter to the gear train, and bypass valves protect the filter while keeping the oil pressure stable across the speed range of the drive.
Pureza del aire de clase 0 para procesos críticos
The ZR 315 VSD is certified to ISO 8573-1 Class 0, the strictest oil quality class of the standard, which sets the total oil carry-over limits at the values the certification measured instead of a declared figure. Together with the ISO 1217 performance rating and the ISO 9001 manufacturing certificate, the machine documents what it delivers to processes that must prove their air quality to auditors.
El secador integrado por calor de compresión
En las versiones «Full Feature», la función de secado utiliza el calor de compresión en lugar de energía externa. En el paquete iMD, toda la función de secado se encuentra dentro de la carcasa del compresor. En el concepto split iMDG, aproximadamente el 60% del caudal principal se enfría en el preenfriador y el posenfriador, mientras que el caudal restante regenera el tambor de adsorción, por lo que el secador no impone ninguna pérdida por purga a la red ni requiere una alimentación eléctrica independiente.

Control y supervisión
The Elektronikon controller of the ZR 315 VSD manages the pressure band, the two drive modules and the dryer, and it logs the operating data that a maintenance team needs. The display shows the state of each module, and the controller communicates with plant systems so a central room can supervise several machines as one supply group. Service planners read the logged hours and the component states directly from the controller, which turns the maintenance plan of the ZR 315 VSD into a schedule instead of a reaction.
Opciones y soluciones de ingeniería
The 200-355 platform carries an options list that adapts the machine to the site: energy recovery units that put the cooling heat to work, sound attenuation packages, connection sets for the water circuit, and control accessories that link the machine into a master-supply network. The build of the ZR 315 VSD is selected at order time, and the Pack, iMD and iMDG concepts share the same base design so a later extension of the plant can add machines of the same family without re-engineering the room.

Applications of the ZR 315 VSD
The ZR 315 VSD fits plants that run a continuous oil-free demand around the clock: glass and bottle lines, tire curing, chemical dosing, central medical and laboratory supplies, and textile mills that dry and shape fibers with clean air. The 10.4 bar(e) maximum covers high-pressure networks directly, and the flow band of 208 to 974 l/s follows the batch rhythm of the production day.
Water cooling makes the ZR 315 VSD a natural choice in plants that already operate a cooling water circuit, because the ZR 315 VSD needs no ductwork to the outside and keeps its rated output in hot plant rooms. Where the site wants dry air without extra dryer hardware, the iMD and iMDG builds deliver Class 0 air with the dew point already controlled inside the supply.
Service and Support Around the ZR 315 VSD
Service access on the ZR 315 VSD follows the layout of the platform: one side of the enclosure carries the routine service points, and the fluid, filter and separator service kits of the ZR 315 VSD match the shared design of the 200-355 family. Atlas Copco backs the installed base with a global service organization, and genuine parts for the ZR 315 VSD are specified in the service plan that ships with the machine.

Preguntas frecuentes
What does the ZR 315 VSD deliver at maximum pressure?
At the maximum setting of 10.4 bar(e) the Pack build produces 208 to 838 l/s (12.5 to 50.3 m3/min), and the Full Feature iMD build produces 304 to 830 l/s (18.2 to 49.8 m3/min) from its minimum setting of 6 bar(e).
Is the ZR 315 VSD water-cooled?
Sí. La letra «R» del nombre del modelo indica que se trata de la gama refrigerada por agua, y el agua de refrigeración abastece al intercooler, al postenfriador, al circuito de aceite y a las camisas del motor a través de tres circuitos independientes.
¿Hasta qué punto está libre de aceite el aire?
La máquina cuenta con la certificación ISO 8573-1 Clase 0, y el diseño sin aceite del elemento no añade aceite al flujo de aire a ninguna velocidad del control VSD+.
¿Cuál es la diferencia entre iMD e iMDG?
Ambos son conceptos de secadores por calor de compresión. El iMD integra el secador dentro del conjunto del compresor, mientras que el iMDG ofrece el secador de tambor como un conjunto técnico independiente que mide 5651 x 1927 x 2150 mm y se instala donde la red de aire lo requiera.
¿Hasta qué punto puede bajar la máquina?
El control VSD+ regula los dos variadores hasta alcanzar el 11% de la velocidad máxima, de modo que el caudal se adapta a la demanda de la planta entre los rangos de presión mínima, efectiva y máxima sin pérdidas por descarga.
How loud is the ZR 315 VSD?
El nivel de presión acústica nominal de emisión en el puesto de trabajo es de 73 dB(A) en las versiones Pack, iMD e iMDG, medido según las normas ISO 2151:2008 e ISO 9614-2, con una incertidumbre total de +/- 3 dB(A).


















Mikael Forsberg –
We scaled from a 250 kW unit to the ZR 315 VSD and the extra flow absorbed our new filling hall without adding a second machine. Both drive modules hold the day profile without unloading, the iMDG dryer came as its own package and the water connections lined up with our existing headers. Seadweer confirmed the build and pressure in one reply.